Review of PEEK implants and biomechanical and immunological responses to a zirconium phosphate nano-coated PEEK, a blasted PEEK, and a turned titanium implant surface.
Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden.
Department of Prosthodontics, Institute of Odontology, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden.
Malmö universitet, Odontologiska fakulteten (OD).ORCID-id: 0000-0001-7488-3588
Promimic AB, AstraZeneca BioVentureHub, Mõlndal, Sweden.
Vise andre og tillknytning
2022 (engelsk)Inngår i: American Journal of Dentistry, ISSN 0894-8275, Vol. 35, nr 2, s. 152-160Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE: To investigate the biomechanical and immunological reactions to coated and non-coated blasted PEEK implants in vivo after 12 weeks and review the associated literature.

METHODS: Two osteotomy sites were performed in each proximal tibia of 10 lop-eared rabbits (n= 4 per rabbit). Each rabbit received a randomly placed (1) blasted zirconium phosphate nano-coated PEEK- (nano-ZrP), (2) blasted PEEK- (PEEK) and (3) titanium implant (Ti) and an empty sham site. At 12 weeks, removal torque of all implants and biological investigation with qPCR was performed. The implant surfaces were analyzed prior to insertion with interferometry, SEM and XPS.

RESULTS: The interferometry analysis showed that there was no difference in roughness for the uncoated PEEK compared to the ZrP coated PEEK implants. The titanium implants were considerably smoother (Sa= 0.23 µm) than the uncoated Sa= 1.11 µm) and ZrP coated PEEK implants (Sa= 1.12 µm). SEM analysis on the PEEK implants corroborated the interferometry results; no difference in structure between the uncoated vs. the ZrP coated PEEK was visible on the micrometer level. At higher magnifications, the ZrP coating was visible in the SEM as a thin, porous network. All tested implants displayed osseointegration with the highest RTQ for nano-ZrP (18.4 Ncm) followed by PEEK (14.5 Ncm) and Ti (11.5 Ncm). All implants activated the immune system, with elevated macrophage and M2 macrophage qPCR markers at 12 weeks compared to the sham site.

CLINICAL SIGNIFICANCE: Nano-ZrP coating improves osseointegration of blasted PEEK implants at 12 weeks of follow-up. Osseointegration of titanium, PEEK and nano-ZrP PEEK is not a normal bone healing process, but rather a shield-off mechanism that appears to be regulated by the innate immune system.

sted, utgiver, år, opplag, sider
Mosher & Linder, Inc. , 2022. Vol. 35, nr 2, s. 152-160
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-56285ISI: 000893228600008PubMedID: 35798711OAI: oai:DiVA.org:mau-56285DiVA, id: diva2:1714399
Tilgjengelig fra: 2022-11-29 Laget: 2022-11-29 Sist oppdatert: 2023-09-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

PubMed

Person

Galli, SilviaAlbrektsson, TomasWennerberg, Ann

Søk i DiVA

Av forfatter/redaktør
Galli, SilviaAlbrektsson, TomasWennerberg, Ann
Av organisasjonen
I samme tidsskrift
American Journal of Dentistry

Søk utenfor DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 38 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf