Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reverse Iontophoretic Extraction of Skin Cancer-Related Biomarkers
Malmö universitet, Fakulteten för hälsa och samhälle (HS), Institutionen för biomedicinsk vetenskap (BMV). Malmö universitet, Biofilms Research Center for Biointerfaces.ORCID-id: 0000-0001-8720-3705
Malmö universitet, Fakulteten för hälsa och samhälle (HS), Institutionen för biomedicinsk vetenskap (BMV). Malmö universitet, Biofilms Research Center for Biointerfaces.ORCID-id: 0000-0001-6254-8539
Malmö universitet, Fakulteten för hälsa och samhälle (HS), Institutionen för biomedicinsk vetenskap (BMV). Malmö universitet, Biofilms Research Center for Biointerfaces.
Univ Bath, Dept Pharm & Pharmacol, Bath BA2 7AY, Avon, England..
Vise andre og tillknytning
2022 (engelsk)Inngår i: Pharmaceutics, ISSN 1999-4923, E-ISSN 1999-4923, Vol. 14, nr 1, artikkel-id 79Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Non-invasive methods for early diagnosis of skin cancer are highly valued. One possible approach is to monitor relevant biomarkers such as tryptophan (Trp) and kynurenine (Kyn), on the skin surface. The primary aim of this in vitro investigation was, therefore, to examine whether reverse iontophoresis (RI) can enhance the extraction of Trp and Kyn, and to demonstrate how the Trp/Kyn ratio acquired from the skin surface reflects that in the epidermal tissue. The study also explored whether the pH of the receiver medium impacted on extraction efficiency, and assessed the suitability of a bicontinuous cubic liquid crystal as an alternative to a simple buffer solution for this purpose. RI substantially enhanced the extraction of Trp and Kyn, in particular towards the cathode. The Trp/Kyn ratio obtained on the surface matched that in the viable skin. Increasing the receiver solution pH from 4 to 9 improved extraction of both analytes, but did not significantly change the Trp/Kyn ratio. RI extraction of Trp and Kyn into the cubic liquid crystal was comparable to that achieved with simple aqueous receiver solutions. We conclude that RI offers a potential for non-invasive sampling of low-molecular weight biomarkers and further investigations in vivo are therefore warranted.

sted, utgiver, år, opplag, sider
MDPI, 2022. Vol. 14, nr 1, artikkel-id 79
Emneord [en]
tryptophan, kynurenine, tryptophan-to-kynurenine ratio, cancer-related biomarkers, non-invasive extraction, bicontinuous cubic liquid crystals
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-50524DOI: 10.3390/pharmaceutics14010079ISI: 000758502900001PubMedID: 35056976Scopus ID: 2-s2.0-85122161916OAI: oai:DiVA.org:mau-50524DiVA, id: diva2:1643407
Tilgjengelig fra: 2022-03-09 Laget: 2022-03-09 Sist oppdatert: 2024-02-05bibliografisk kontrollert
Inngår i avhandling
1. Biophysical aspects of the skin barrier: towards increased non-invasive extraction and optimized biomarker sampling
Åpne denne publikasjonen i ny fane eller vindu >>Biophysical aspects of the skin barrier: towards increased non-invasive extraction and optimized biomarker sampling
2021 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The skin provides a link to the body’s health via its rich variety of high and low molecular weight biomarkers, reflecting both systemic diseases (e.g., cancer, diabetes) and local skin disorders (e.g., atopic dermatitis, psoriasis). Non-invasive monitoring of disease-specific biomarkers on the skin surface provides a highly attractive diagnostic procedure as alternative to current practices that normally are biopsy-based and invasive. In order to succeed with non-invasive topical diagnostics, the sampling of biomarkers should proceed in a highly accurate and reproducible manner. Further, a major challenge to achieve this goal is to overcome the outermost skin layer (the stratum corneum, SC) that acts as a remarkable permeability barrier, restricting molecular diffusion in and out of our body, including diffusion of potential biomarkers.

The primary aim of this thesis is to achieve an optimized and reproducible noninvasive sampling of endogenous biomarkers from the skin surface. Here, water plays a crucial role as the hydration degree of the SC has a strong influence on the diffusion of molecules across the skin barrier. In particular, fully hydrated skin is expected to be optimal for increased diffusion of biomarkers in the skin tissue, favoring efficient extraction.

Considering this, to develop a suitable sampling matrix for non-invasive extraction, it is very important to optimize the matrix so that it has a good ability to hydrate the skin as well as a high capacity to absorb the biomarker and finally allow for analytic quantification. The main questions in this thesis are as follows. (i) How long time does it take to reach a stable level of skin hydration? (ii) How do the intrinsic properties of sampling matrices influence the extraction of biomarkers? (iii) What are the effects of the sampling matrices on the biophysical properties of the skin barrier?(iv) Are hydrogels and bicontinuous cubic liquid crystals suitable matrices for noninvasive sampling of endogenous biomarkers? (v) Is reverse iontophoresis a suitable technique to further enhance the extraction endogenous biomarkers?

The hydration of the skin is investigated in vivo and in vitro in order to estimate the time to reach stable hydration level. We show that skin hydration proceeds in two distinct stages with different rates of change of the electrical impedance response and conclude that stable conditions are obtained approximately after 60 min of hydration. We explore the novel approach of using lipid-based bicontinuous cubic liquid crystalline phases as matrices for non-invasive sampling of biomarkers in vivo and invitro and compare them with hydrogel-based materials.

From these investigations, we conclude that both kind of materials show promising capacity of hydrating the skin and collect skin-derived biomarkers. However, the cubic phases are shown to havea bout twice as high extraction capacity, as compared to hydrogels. Further, we show that reverse iontophoresis enhances extraction of a potential cancer biomarker in vitro by at least an order of magnitude, as compared to passive diffusion. Taken together, the results obtained in this thesis can serve as a point-of-departure for future applications based on non-invasive sampling of disease-related biomarkers from skinin clinical diagnostics.

sted, utgiver, år, opplag, sider
Malmö: Malmö universitet, 2021. s. 70
Serie
Malmö University Health and Society Dissertations, ISSN 1653-5383 ; 2021:10
HSV kategori
Identifikatorer
urn:nbn:se:mau:diva-48311 (URN)10.24834/isbn.9789178772254 (DOI)9789178772247 (ISBN)9789178772254 (ISBN)
Opponent
Veileder
Merknad

Paper II published in dissertation as manuscript.

Paper IV published in dissertation as manuscript with title Non-invasive, Topical Sampling of Potential Skin Cancer Biomarkers,Kynurenine and Tryptophan: Study on Healthy Volunteer

Tilgjengelig fra: 2021-12-21 Laget: 2021-12-21 Sist oppdatert: 2023-10-19bibliografisk kontrollert

Open Access i DiVA

fulltext(3405 kB)128 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3405 kBChecksum SHA-512
ded2bfd5ca940bfa2166928dcb4f3647be88040e0a93f1dd752ede6bf1ed62fc3eba38684bfaeca4d246517e6c863a297f27485f17b2ce8c5fec51136a145792
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Morin, MaximBjörklund, SebastianJankovskaja, SkaidreRuzgas, TautgirdasEngblom, Johan

Søk i DiVA

Av forfatter/redaktør
Morin, MaximBjörklund, SebastianJankovskaja, SkaidreDelgado-Charro, Maria BegonaRuzgas, TautgirdasGuy, Richard H.Engblom, Johan
Av organisasjonen
I samme tidsskrift
Pharmaceutics

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 129 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 274 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf