Optimering av personalstrålskydd vid administration av fluor-18 märkt läkemedel
Malmö universitet, Fakulteten för hälsa och samhälle (HS), Institutionen för biomedicinsk vetenskap (BMV).
2021 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Optimization of radiation protection for staff when injecting fluorine-18 labelled radiopharmaceuticals (engelsk)
Abstract [sv]

På Nuklearmedicin, VO Bild och Funktion på Skånes universitetssjukhus i Malmö sker dagligen administrering med fluor-18 (18F) märkta läkemedel, vilket medför exponering för joniserande strålning till personal i verksamheten. Strålskyddsförordningen i Sverige, har riktlinjer för dosgränser för att förhindra eventuella negativa hälsoeffekter på både allmänheten och arbetstagare som är aktiva i verksamhet med joniserande strålning. Syftet med studien var att studera om det föreligger signifikant skillnad i stråldos till personalens fingrar respektive kropp efter administrering med 18F märkt läkemedel, beroende på när borttagning av perifer venkateter (PVK) sker. Mätningarna utfördes direkt efter administrering av 18F-märkt läkemedel samt efter bildtagning. I studien utfördes 44 mätningar på 11 av personalen vid nuklearmedicinska avdelningen, varav 22 mätningar utfördes efter administration av 18F-märkt läkemedel och 22 mätningar efter bildtagning. Efter 22 mätningar visar resultaten ett medelvärde av den ekvivalenta dosen till fingrarna direkt efter injektion på 0,20 μSv/MBq och efter bildtagning på 0,18 μSv/MBq. Medelvärdet av den uppmätta effektiva dosen på 0,004 μSv/MBq efter injektion och 0,003 μSv/MBq efter bildtagning är i samma storleksordning. Ett Mann-Whitney U-test redovisade ett p-värde på >0,05, vilket tyder på att det inte föreligger någon signifikant skillnad i stråldos mellan de två olika metoderna vid borttagning av PVK. 

Abstract [en]

At the Nuclear medicine department at Skane University Hospital in Malmoe, the staff inject fluorine-18 labelled radiopharmaceuticals on a daily basis, which entails exposure of radiation dose. The Swedish Radiation Protection Ordinance prescribe dose limits, which works as requirements to prevent and minimize risks for future negative health effects to the public and workers handling ionizing radiation. The aim and purpose of the study was to study whether there is a statistically significant difference of radiation dose to the staffs fingers and body, when injecting fluorine-18 labelled radiopharmaceuticals, depending on when the removal of the peripheral venous catheter (PVK) is performed. The measurements were performed after the injection of fluorine-18 labelled radiopharmaceutical and after the imaging of the patients. In this study 44 measurements were performed, of which 22 measurements were performed after the injection of 18F-labelled radiopharmaceutical and 22 measurements after the medical imaging. The measurements were performed on 11 staff members in the Nuclear Medicine department in Malmoe. The results of 22 measurements showed a mean value of the equivalent doses to the fingers after injection showed 0,20 μSv/MBq and after the medical imaging of the patient of 0,18 μSv/MBq. The mean value of effective dose was entailed to 0,004 μSv/MBq after injection and 0,003 μSv/MBq after imaging. A Mann-Whitney U-test was performed and reported a p-value of >0,05, which indicates that there is no significant difference in radiation dose to the staff between the two different methods of removing the PVK. 

sted, utgiver, år, opplag, sider
2021. , s. 24
Emneord [en]
Fluorine-18, equivalent dose, effective dose, thermoluminescent detectors, personal electronic dosimeter.
Emneord [sv]
Fluor-18, ekvivalent dos, effektiv dos, termoluminicenta detektorer, personlig elektronisk dosimeter.
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-43708OAI: oai:DiVA.org:mau-43708DiVA, id: diva2:1568354
Eksternt samarbeid
Region Skåne
Utdanningsprogram
HS Biomedicinsk laboratorievetenskap
Veileder
Examiner
Tilgjengelig fra: 2021-11-11 Laget: 2021-06-17 Sist oppdatert: 2021-11-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Søk i DiVA

Av forfatter/redaktør
Ahmed, Ammar
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 182 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf