Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Impact of peri-implant buccal bone thickness, implant fixture diameter, abutment and/or prosthetic reconstruction material on the accuracy of Cone Beam Computed Tomography to assess peri-implant buccal bone level: an in vitro study in pig jaw
Malmö universitet, Odontologiska fakulteten (OD).
2018 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

Abstract Aim: To evaluate the impact of peri-implant buccal bone thickness, implant fixture diameter, abutment material (Titanium Ti, Zirconium Zr) and/or prosthetic reconstruction material (metal ceramic vs ceramic) on the accuracy of Cone Beam Computed Tomography (CBCT) to assess peri-implant buccal bone level. Materials and methods: Titanium implants were inserted into 36 blocks of pig mandible in a way to create variable buccal bone thicknesses groups, each group with 12 blocks; group 1 (0.5-1 mm), group 2 (>1-1.5 mm) and group 3 (>1.5-2 mm), half of each group received a dehiscence which was created of variable extent. Two groups regarding abutment-crown material; (Ti abutment with CoCr crown, Zr abutment with Zr crown) and implant diameter; (standard/narrow) were assessed. Dehiscences were measured on CBCT image using 2 programs (i-Dixel and Photoshop) and were compared to the gold standard. Results: Thin buccal bone thickness group (0.5-1 mm) had major impact on the accuracy of CBCT to correctly detect and measure the extent of a bony dehiscence. No differences were detected between standard or narrow diameter implant and between TiTi/CoCr combination and TiZr/Zr combination in regards to possibility of CBCT to detect and evaluate accurately the extent of a bony dehiscence. Conclusion: Thin peri-implant buccal bone (≤ 1 mm) has a negative effect on the accuracy of CBCT to assess peri-implant buccal bone level. The possibility to identify and to assess the extent of peri-implant buccal bone dehiscence in CBCT was hardly affected by using different abutments and crown materials and different implant diameters.

sted, utgiver, år, opplag, sider
Malmö universitet/Odontologiska fakulteten , 2018.
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-19922Lokal ID: 26517OAI: oai:DiVA.org:mau-19922DiVA, id: diva2:1479767
Utdanningsprogram
OD Dental Science: Master Program
Veileder
Examiner
Tilgjengelig fra: 2020-10-27 Laget: 2020-10-27 Sist oppdatert: 2022-06-27bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 93 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf