Publikationer från Malmö universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Comparison of Tapered and Nontapered Implants in the Minipig
University of Texas Health Sciences Center, Department of Periodontics, San Antonio, TX, United States.
Malmö högskola, Odontologiska fakulteten (OD).ORCID-id: 0000-0001-8161-3754
Institut Straumann, Department of Surgical and Clinical Research, Basel, Switzerland.
Institut Straumann, Department of Surgical and Clinical Research, Basel, Switzerland.
Vise andre og tillknytning
2016 (engelsk)Inngår i: International Journal of Oral & Maxillofacial Implants, ISSN 0882-2786, E-ISSN 1942-4434, Vol. 31, nr 6, s. 1341-1347Artikkel i tidsskrift (Fagfellevurdert)
Abstract [en]

PURPOSE: Tapered implants are thought to result in equivalent long-term stability and marginal peri-implant bone height in comparison to cylindrical implants. The goal of this study was to compare the primary stability and osseointegration of a novel bone-level tapered-wall implant to a control bone-level cylindrical implant with exactly the same surface characteristics, in a direct side-by-side comparison in an animal model. MATERIALS AND METHODS: Mandibular premolars and first molars were extracted in 11 G.ttingen minipigs, and healing was allowed for 3 months. Six implants were placed with a 4-week surgical lag time between hemimandibles (three per side), and either immediately loaded (first implantation time point) or submerged (second implantation time point). Eight-mm-long × 4.1-mm-diameter titanium screw-type bone-level implants with tapered (two per side) and cylindrical bodies (one per side) were used (Institut Straumann); insertion torque and implant stability were measured, and the soft tissue was closed. Standardized radiographs were taken at implant placement and at sacrifice. Following a healing period of 1 month from the last surgical intervention (8 weeks total healing time for loaded implants; 4 weeks total healing time for nonloaded implants), the animals were sacrificed and mandibular blocks were harvested for nondecalcified histologic and histomorphometric analysis. RESULTS: All implants were integrated radiographically and osseointegrated histologically. Maximum insertion torque measurements and implant stability quotient values showed no significant difference between tapered and cylindrical implants. Histomorphometric analysis also resulted in comparable bone-to-implant contact values between the implant types and similarly limited marginal peri-implant bone resorption; no significant differences were observed regarding all the evaluated parameters between the groups, regardless of the loading regime. CONCLUSION: In a direct side-by-side comparison, in an intraoral minipig model, a novel bone-level tapered screw implant with an SLActive surface showed comparable clinical and histologic outcomes to a parallel-walled bone-level screw implant with an SLActive surface.

sted, utgiver, år, opplag, sider
Quintessence , 2016. Vol. 31, nr 6, s. 1341-1347
Emneord [en]
bone-level implants, bone remodeling, osseointegration, peri-implant bone level, tapered implant
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-15321DOI: 10.11607/jomi.4712ISI: 000394447900017PubMedID: 27861658Scopus ID: 2-s2.0-84998953645Lokal ID: 23826OAI: oai:DiVA.org:mau-15321DiVA, id: diva2:1418842
Tilgjengelig fra: 2020-03-30 Laget: 2020-03-30 Sist oppdatert: 2024-06-17bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Stavropoulos, Andreas

Søk i DiVA

Av forfatter/redaktør
Stavropoulos, Andreas
Av organisasjonen
I samme tidsskrift
International Journal of Oral & Maxillofacial Implants

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 97 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf