Effect of electric potential and current on mandibular linear measurements in cone beam CT
Department of Radiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Department of Anatomy, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
Malmö högskola, Odontologiska fakulteten (OD).
2012 (engelsk)Inngår i: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, E-ISSN 1476-542X, Vol. 41, nr 7, s. 578-582Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objectives The purpose of this study was to compare mandibular linear distances measured from cone beam CT (CBCT) images produced by different radiographic parameter settings (peak kilovoltage and milliampere value). Methods 20 cadaver hemimandibles with edentulous ridges posterior to the mental foramen were embedded in clear resin blocks and scanned by a CBCT machine (CB MercuRayTM; Hitachi Medico Technology Corp., Chiba-ken, Japan). The radiographic parameters comprised four peak kilovoltage settings (60 kVp, 80 kVp, 100 kVp and 120 kVp) and two milliampere settings (10 mA and 15 mA). A 102.4 mm field of view was chosen. Each hemimandible was scanned 8 times with 8 different parameter combinations resulting in 160 CBCT data sets. On the cross-sectional images, six linear distances were measured. To assess the intraobserver variation, the 160 data sets were remeasured after 2 weeks. The measurement precision was calculated using Dahlberg's formula. With the same peak kilovoltage, the measurements yielded by different milliampere values were compared using the paired t-test. With the same milliampere value, the measurements yielded by different peak kilovoltage were compared using analysis of variance. A significant difference was considered when p < 0.05. Results Measurement precision varied from 0.03 mm to 0.28 mm. No significant differences in the distances were found among the different radiographic parameter combinations. Conclusions Based upon the specific machine in the present study, low peak kilovoltage and milliampere value might be used for linear measurements in the posterior mandible.

sted, utgiver, år, opplag, sider
British Institute of Radiology , 2012. Vol. 41, nr 7, s. 578-582
Emneord [en]
cone-beam computed tomography, dental implants, mandible
HSV kategori
Identifikatorer
URN: urn:nbn:se:mau:diva-6123DOI: 10.1259/dmfr/51664704ISI: 000309636800008PubMedID: 22499132Scopus ID: 2-s2.0-84866619387Lokal ID: 15653OAI: oai:DiVA.org:mau-6123DiVA, id: diva2:1403011
Tilgjengelig fra: 2020-02-28 Laget: 2020-02-28 Sist oppdatert: 2023-07-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Petersson, Arne

Søk i DiVA

Av forfatter/redaktør
Petersson, Arne
Av organisasjonen
I samme tidsskrift
Dento-Maxillo-Facial Radiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 16 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf